W Sections

W250x89

Section Property Table for W250x89

W: Thickness of web, mm. B: Width of flange , mm. D: Deppth of section, mm T: Thickness of flange, mm.
W: 10.7 B: 256 D:260 T: 17.3
BT: Width-to-thickness ratio . HW: Depth-to-thickness ratio of web. K: Distance between outer face of flange and web-toe of fillet, mm. K1: Distance between middle line of web and flange-toe of fillet, mm.
BT: 7.4 HW: 21.1 K: 34 K1: 21
Dn_i: Nominal depth of section (Imperial units), in. Dnom: Nominal depth of section, mm. Mass: Mass per length, kg/m. Wt_i: Weight per length (Imperial units), lb/ft.
Dn_i: 10 Dnom: 250 Mass: 89 Wt_i: 60
A: (Cross-sectional area, mm^2) J: St-Venant torsional constant, mm^4. Cw: Warping constant, mm^6. Sw: Warping statical moment, mm^4.
A: 11400 J: 1040 Cw: 713 Sw: 17.2
Ix: Moment of inertia about axis XX, mm^4. Sx: Elastic section modulus about axis XX, mm^3. Rx: Radius of gyration about axis XX, mm. Sw: Plastic modulus about axis XX, mm^3.
Ix: 143 Sx: 1100 Rx: 112 Zx: 1230
Iy: Moment of inertia about axis YY, mm^4. Sy: Elastic section modulus about axis YY, mm^3. Ry: Radius of gyration about axis YY, mm. Zy: Plastic modulus about axis YY, mm^3.
Iy: 48.4 Sy: 378 Ry: 65.1 Zy: 574
Qf: Statical moment at point in flange in line with web face, mm^3. Qw: Statical moment at mid-depth in web, mm^3. SA: Surface area per metre, m. Section: Structural Member
Qf: 257 Qw: 605 SA: 1.52 Section: W250x89